Interface Out 1 ──► loopback cable ──────────────────────────────► interface In 1 "Ref ch" (the reference)
Interface Out 2 ──► console input ──► main bus ──► system processor ──► tops + subs
Measurement mic ─────────────────────────────────────────────────► interface In 2 "Mic ch"
Set the Output channel to Out 1+2. Out 1 loops straight back into In 1 and is the reference; Out 2 feeds the console.
Keep the console's noise channel clean: no compressor or gate, flat EQ, routed to the main bus.
Reference and mic must come in on the same audio interface.
Turn off sleep and screen lock on the laptop and keep the app on screen while measuring. If the app is paused, a yellow message asks you to press Reset avg.
Alternative: take the reference from a console output before the system processor instead of the loopback. Needed if you use the console's own noise generator. The alignment result is the same.
Use Chrome or Edge. If only 2 input channels appear, use input 1 for the reference and input 2 for the mic.
Turn the mic preamp up so the Mic meter reads around −20 to −10 dBFS with noise playing. Never let it clip.
2. Measure the top and lock the delay
Put the mic on-axis of the left top, about ⅔ back in the audience. Mute the right top.
Mute the subs. Turn pink noise on.
Press Find delay (F). The top's impulse peak in the bottom panel should now be at 0 ms.
Wait for the averages to settle, then name it "Top L" and Capture (Space).
3. Measure the whole sub array
Mute the top and unmute all subs (with their arc delays). Do not press Find delay.
Press Reset avg (R), wait for the averages to settle, then capture "Sub array".
4. Let the helper calculate
Choose A = Top L, B = Sub array, and set the band to where the two magnitudes overlap (about equal level).
Press Find best alignment. It tells you which one to delay, by how much, and whether polarity should be flipped.
Press Show predicted sum to see the expected result before you change anything.
Low-frequency phase repeats every period, so there can be more than one solution. Usually choose the smallest delay with a good match.
5. Apply and verify
Enter the delay (and polarity) in the system processor, not in this app.
Measure the top again (same compensation delay). Its phase should now lie on top of the sub array in the crossover band.
Turn top + subs on together and capture "Top L + subs". In the crossover band it should be higher than each one alone, with no dip.
Copy the delay to the right top, then walk around and check other positions.
Keyboard
Space capture · F find delay · R reset average · G pink noise on/off
Traces are stored in this browser. Use Export to save them as a file. ↺ Reset settings (top bar, click twice) restores all settings to their defaults. Traces and selected devices are kept.